Page 1

Installation & Operating InstructionsSeries 3100 Differential Pressure Transmitter302-066SUPERSEDES: April 1, 2012 EFFECTIVE: August 1, 2012

Page 2

104. INSTALLATION:4.1 Overview:The information in Chapter 4 explains installation.4.2 Safety Messages:Procedures and instructions in this chapter

Page 3 - Table of Contents

114.7.4 Wiring (Loop Configuration):4.7.4.1 Loop Configuration:The Taco 3100 Pressure Transmitters use a two-wire system forpower, 4~20mA analog s

Page 4

12There are ground terminals on the inside and outside of the trans-mitter. Either of these terminals may be used.Use 600V insulated PVC wire for grou

Page 5

135.2.1 Warning:5.2.2 Current to Passive Mode Configuration:For multi-drop mode the current output must be configured as pas-sive mode. Please disrega

Page 6 - 2-14 NPT Female

14transmitter’s analog output to a selected upper and lower rangeand can be done with or without an applied pressure. 4-20mAconfiguration do

Page 7 - Figure 1

156.4 Hardware Maintenance:The Taco 3100 Smart Transmitter has no moving parts andrequires little maintenance. If a transmitter fails,

Page 8 - Zero/Span

16TACO, INC., 1160 Cranston Street, Cranston, RI 02920 Telephone: (401) 942-8000 FAX: (401) 942-2360.TACO (Canada), Ltd., 8450 Lawson Road, Unit

Page 10

3Table of ContentsPage Section 1.0 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 11 - Figure 10

41. INTRODUCTION:The 3100 Smart Pressure Transmitter is calibrated at the factorybefore shipping. To ensure correct and efficient use of the instru-me

Page 12 - Figure 14

52.1 Unpacking Transmitters:When moving the transmitter to the installation site, keep it in theoriginal packaging. Unpack the transmitter at the inst

Page 13 - Figure 17

minal. Be sure to connect the grounding lead of the dielectricstrength tester to the ground terminal.3. Set the current limit on the dielectric streng

Page 14 - TABLE 8.1

Only qualified personnel can install the transmitter.3.4 Fail Mode Alarm:Taco Smart Pressure Transmitter automatically and continuouslyperforms self

Page 15

83.7 Configuration of Zero and Span Procedures:The ZERO and SPAN Buttons are under the transmitter’s name-plate. The ZERO, SPAN, ZERO TRIM, ZERO ADJ,

Page 16 - TACO, Inc

98. To save the settings, press the Zero+Span buttons until theSelInc message appears.• CHANGE UNITS1. Access the menu by pressing the Zero+Span butto