rise. In addition, if the temperature of the gas is hotter than ambient air or mixed with gases that are
lighter than air, it could also rise.
How rapidly will the gas diffuse into the ambient air? Select a location for the sensor that is close to the
anticipated source of a gas leak.
Wind or ventilation characteristics of the immediate area must also be considered. Movement of air may
cause gas to accumulate more heavily in one area than in another. The detector should be placed in the
areas where the most concentrated accumulation of gas is anticipated. For outdoor applications with
strong wind conditions, it may require the sensors to be mounted closer together and on the down wind
side, to the anticipated area of a gas leak. Also take into consideration for indoor applications, the fact
that many ventilation systems do not operate continuously.
The sensor should be accessible for maintenance.
Excessive heat or vibration can cause premature failure of any electronic device and should be avoided
if possible.
Follow all national and local installation codes and practices.
The SEC 3100 has three (3) ¾” NPT threaded connectors for mounting and wiring the sensor and
transmitter into a permanent installation.
Field wiring connections are made on the backside of the SEC 3100 printed circuit board (PCB). For wiring
details refer to Figure 2 in the back of the manual.
Power wire sizing:
0 to 500 feet, recommended wire gauge size 16 AWG
501 to 1000 feet, recommended wire gauge size 14 AWG
Shielded cable is recommended. Wiring should be installed in medal conduit with no other cabling in the
same conduit.
Warm-up
When power is applied to the SEC 3100, it enters a one (1) minute warm-up mode. The output current will
be 0.8 mA during the warm up time period. At the end of the warm-up period with no faults present, the
SEC 3100 automatically enters the normal operating mode (4.0 mA with no gas present). If a fault is
present after warm-up, the detector current output and LCD will indicate a fault. The Fault LED will also
indicate the fault.
Normal
In the normal operating mode, the 4 to 20 mA signal levels correspond to the detected gas concentration.
The transmitter continuously checks for and displays system faults or initiation of calibration and
automatically changes to the appropriate mode.
Vue de la page 5
1 2 3 4 5 6 7 8 9 10 11 ... 28 29

Commentaires sur ces manuels

Pas de commentaire

Razor E125 manuals

Owner’s manuals and user’s guides for Scooters Razor E125.
We providing 1 pdf manuals Razor E125 for download free by document types: User Manual






More products and manuals for Scooters Razor

Models Document Type
Mobility Scooter 13114501 User Manual   Razor Mobility Scooter 13114501 User's Manual [pl] , 12 pages
eSpark Owner's Manual   Razor eSpark Owner`s manual, 14 pages
E100 series Owner's Manual   Razor E100 series Owner`s manual, 12 pages
Powerwing Silver 20036002 User Manual   Reward yourself., 13 pages
Bistro Owner's Manual   Razor Bistro Owner`s manual, 12 pages
Vapor Silver User Manual   and 3″ Substrate Heater Manual, 18 pages
Crazy Cart Owner's Manual   Razor Crazy Cart Owner`s manual, 16 pages
E300s Owner's Manual   Razor E300s Owner`s manual, 13 pages
Pocket Rocket 15120040 Owner's Manual   Razor Pocket Rocket 15120040 Owner`s manual, 13 pages
E200 Series Owner's Manual     Razor E200 Series Owner`s manual, 31 pages
Dirt Quad Owner's Manual   Razor Dirt Quad Owner`s manual, 11 pages
Scream Machine Owner's Manual   Razor Scream Machine Owner`s manual [sl] , 14 pages
DUNE BUGGY Owner's Manual   Razor DUNE BUGGY Owner`s manual, 10 pages
DIRT QUAD 25117460 Owner's Manual   Razor DIRT QUAD 25117460 Owner`s manual, 11 pages
Ground Force Owner's Manual   Razor Ground Force Owner`s manual, 12 pages
Daisy Owner's Manual   Razor Daisy Owner`s manual, 12 pages
Dirt Rocket MX350 Owner's Manual   Razor Dirt Rocket MX350 Owner`s manual, 14 pages
Espark 13111290 Owner's Manual   Razor Espark 13111290 Owner`s manual, 14 pages
Ecosmart metro 13114501 Owner's Manual   Razor Ecosmart metro 13114501 Owner`s manual, 12 pages
Accelerator Series Service Manual   Razor Accelerator Series Technical data, 50 pages